Class I Hospital Emergency Equipment Ceiling Operating Lamp 80000Lux 160000 lux
Contact Person : JUCCY
Phone Number : 0086-17717698563
WhatsApp : +8617717698563
Minimum Order Quantity : | 1pc | Price : | $4,099.00 - $5,499.00/Sets |
---|---|---|---|
Packaging Details : | Standard exporting package | Delivery Time : | about 10 days |
Payment Terms : | T/T, Western Union,Payoneer | Supply Ability : | 50000 Set/Sets per Month medical CPR equipment |
Place of Origin: | China | Brand Name: | SUCE |
---|---|---|---|
Certification: | CE,ISO13485 | Model Number: | HS02 |
Detail Information |
|||
Type: | First-Aid Devices | Instrument Classification: | Class II |
---|---|---|---|
Power Source: | Electricity | Product Name: | CPR Machine |
Pressing Depth: | 30mm~65mm Adjustable | Pressing Release Rate: | 1:1 |
Pressure Relief Valve: | 0.65Mpa | Ventilation Quanity: | 500ML No Adjust,error:±10% |
Application: | Operating Room | Press The Ventilation Ratio: | 30:2 Continuously Adjustable;,error:±1 Time |
Pressing Frequency: | 100times/ Min,110times/ Min,120times/ Min Error:±1 Time | Certificate: | CE ISO |
Warranty: | 12 Months |
Product Description
Waterproof Multi-function Cardiopulmonary Resuscitation Machine for Sale
Auto-CPR Device HS02 parameter |
1. Pressing depth:30mm~65mm adjustable,one type:5mm,error:±2mm; |
2. Pressing release rate:1:1 ; |
3. Pressure relief valve:0.65Mpa;error:±0.12Mpa; |
4. Pressure of gas road is no less than 1Mpa; |
5. Ventilation quanity:500ML no adjust,error:±10%; |
working pressure:≤816.4N ; |
6. Input power(DC):≤17W; AC:≤54W; |
7. Press the ventilation ratio:30:2 continuously adjustable;,error:±1 time; |
8. Pressing frequency: 100times/ min,110times/ min,120times/ min error:±1 time; |
9. The fastness of fastening band fastness is not less than 100N; |
10. The thickness range of patients was 155 to 305MM. |
11. The pressure is not enough to alarm, the pressure depth is reduced automatically, and the manual recovery after air pressure recovery must be deep. |
12. Electricity, according to the low voltage alarm, start the suspended function; |
13. Default mode:Press the ventilation ratio: 30: 2,press depth 30mm,press frequence 100 pcs/min. Ventilation quanity 500ML |
14. Safety requirements refer to medical electrical appliances safety standard GB 9706.1-2007, electromagnetic compatibility standard YY05052012; |
15. Earthquake Resistance |
16. Drop resistance |
17. The enclosure protection level is IP55 (dustproof and water spray); |
18. Noise≤70dB ; |
19. Working environment : a)Temperature:-20℃~55℃; |
b)Relative temperatur:10%~90%; |
c)Atmospheric pressure:500hPa~1060hPa. |
Enter Your Message