Send Message
Contact Us

Contact Person : JUCCY

Phone Number : 0086-17717698563

WhatsApp : +8617717698563

Free call

Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light

Minimum Order Quantity : 1pc Price : $290.00 - $1,300.00/Sets
Packaging Details : export standard carton package Delivery Time : about 5 days
Payment Terms : T/T, Western Union,Payoneer Supply Ability : 500 Parcel/Parcels per Month shadowless surgical light
Place of Origin: Shanghai, China Brand Name: keling or OEM
Certification: CE Model Number: KL04L.III

Detail Information

Power Source: Electric Warranty: 1 Year
After-sale Service: Online Technical Support Material: Metal, Plastic, Steel
Shelf Life: 1years Quality Certification: Ce
Instrument Classification: Class I Safety Standard: GB15979-2002
Type: Operation Illuminating Lamps Product Name: Shadowless Surgical Light
Input Power: 120VA Rated Voltage For Bulbs: AC24V
Rated Power For Bulbs: 25W Luminance: 40000lx
Color Temperature: 4000±500K Temperature Rise: 100-240V 50/60HZ
Storage Cells Suggested: ≤10℃ Atmospheric Pressure: 800~1060hpa
Port: Shanghai,tianjin,beijing
High Light:

Class I shadowless operating lamp

,

Portable shadowless surgical light

,

Operation Lamp Medical Device Equipment

Product Description

Product Description

Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light 0

Operation Lamp With High Quality Portable Shadowless Surgical Light

1. Scope of application

KL04L.III shadowless operation lamp is fit for illumination in operating rooms.

2. Structure and characteristics

This shadowless operation lamp adopts light sources from different positions for focus to eliminate shadows of different parts of medical workers by adjusting knob. 

    Safety class: Type B of Class I

Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light 1

Environment conditions for transportation and storage:

Ambient temperature:-40℃~55℃

Relative humidity of operating environment:≤85%

Atmospheric pressure:800~1060hpa

3. Technical parameters

Input power: 120VA

Rated voltage for bulbs: AC24V;

Rated power for bulbs: 25W;

Luminance: 40,000lx

Color temperature: 4000±500K;

Temperature rise: ≤10℃

Movements: Y-shaped tube moves up & down: ≥38°

Y-shpaed tube moves left & right: ≥150°

Lamp head rotates around the Y-shaped tube: ≥110°

 

4. Installation and operation

(1) Follow the assembling illustration (picture 1) for installation. Get the upper column (9 in picture 1) connected with the lower column (11 in picture 1), and then have them installed on the lamp seat (12 in picture 1). It shall be noted that the bolts on the upper column (9 in picture 1) shall be installed in the direction as shown on the illustration. Then, install the counterpoise (7 in picture 1), lamp holder and handle in order. Limit bolts (6 in picture 1) shall be installed on the lamp holder in advance. Insert the “Y” shaped rotational bracket (4 in picture 1) into the lifting pipe of the counterpoise. Tighten the limit bolts aiming at the groove in the “Y” shaped axis (appropriate force is required to pull the lamp holder, and meanwhile turn the lamp holder to see whether it is targeting at the groove). Then, install the fixing bolt and adjustment knob to the extent the lamp holder is not over-tightened in right and left turn and is able to keep balance freely”.

(2) Range of movement: The up-and-down swing between Y-shaped bracket and

lamp holder (4 and 3 in picture 1) and the counterpoise shall be more than 400, the swing of the lamp holder shall be more than 1500, and the back-and-forth movement shall be more than 1000.

(3) Balance adjustment: generally, the balance mechanism has been well adjusted before delivery. In case of imbalance, place follow the relevant method(s) in table 1 for solution.

(4) Adjustment for focusing: when the lamp is connected with the power supply and is switched on, all the bulbs shall work normally.  Turn the focusing knob (2 in picture 1) to the extent that the light shall be focus into bright spot in the diameter of 100mm~200mm on a surface 1000mm away from the lamp-house.

(5) Use: the lamp surface shall keep a distance of 900~1100mm from the object. Adjust the focusing knob so that the light will focus on the surface of the object. Adjust the angle of the lamp holder, and the lamp holder shall be able to turn and keep balance freely within the range as shown in picture 1. The operation shall be flexible and convenient.

(6) Stop: To stop the use of the lamp, it’s necessary to switch off the lamp holder, then switch off the emergent power supply cabinet and finally take the plu out of the mains socket.

5 Precautions

(1) The lamp shall be installed by a professional mechanical and electrical

installation worker.

(2) Reliable ground protection is required for the product.

(3) Fastening pieces to different parts shall be examined regularly to prevent accident arising from loosening and falling off.

(4) Never dismantle the lamp at will to prevent electric shock.

Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light 2

6. Maintenance and servicing

(1) All the moving parts shall be lubricated with oil or other appropriate lubricant regularly to keep them flexible in use.

(2) The transparent pieces and the reflector shall be cleaned regularly by wiping with means of absorbent gauze and spirit.

(3)In case of aging or stripping, the reflector shall be replaced by a new one.

(4) The solutions for imbalance are as the following:

No.

Phenomenon

Solution

1

The lamp holder springs back or has free drop when having up-and-down swing.

Adjust the damper (15 in picture 1) in the balance cabinet with a screwdriver till the lamp holder up and down properly and can maintain balance freely.

2

Lamp holder so over tightened that its back-and-forth movement is hampered or it cannot maintain at any position freely.

Adjust the six bolts connecting the two sides of the lamp holder and the Y-shaped bracket till the lamp holder is appropriately tightened to ensure appropriate back-and-forth movement and free balance and positioning.

 

(5) Electrical problems and solutions

 

No.

Problem

Cause

Solution

1

The lamp does not work when the switch is turned on

1. Problem in the power supply;

2. Fuse broken;

3. Problem in the switch;

4. Transformer to the lamp   damaged;

5. Circuit damaged

1.An electrician is required to conduct repair;

2.Change the fuse;

3.Replace the switch with one in the same specifications;

4.Change the transformer;

5.Examine the circuit and repair;

2

Some of the bulbs do not work.

1. Bulb(s) damaged;

2.  Bulb holder(s) damaged;

1. Discharge the transparent dust shield and replace the bulb with one of the same specifications;

2. Discharge the cover to the lamp holder, and change the lamp holder.

(6) The service life of the operational lamp is 10 years.

Notice: No additional notice is to be provided for the change of dimensions and technical parameters, if any.

Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light 3

Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light 4

 

Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light 5Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light 6Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light 7Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light 8Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light 9Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light 10  

Company Information

Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light 11

 

Packaging & Shipping

Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light 12

Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light 13Operation Lamp Medical Device Equipment Portable Shadowless Surgical Light 14

You Might Be Into These
Get in touch with us

Enter Your Message

sucehk@outlook.com
+8617717698563
17717698563
0086-17717698563